SWEP AHRI



SWEP A is our AHRI Certified® range of Brazed Plate Heat Exchangers. If you are looking for the additional security of thirdparty verified performance for your HVAC systems, this is the choice.

SWEP BPHEs are generally approved by listed below certification organizations: 


SWEP A is our AHRI Certified® range of Brazed Plate Heat Exchangers. If you are looking for the additional security of thirdparty verified performance for your HVAC systems, this is the choice.

The AB5T enables efficient heat exchange in applications with small flows and extreme demands for compactness. Easy to install and use, the product is small yet versatile, which makes it a good choice for small oil or water coolers.

Third party approvals

SWEP BPHEs are generally approved by listed below certifi cation organizations: Europe, Pressure Equipment Directive (PED) America, Underwriters Laboratories Inc (UL) Japan, Kouatsu-Gas Hoan Kyoukai (KHK) Additionally SWEP holds approvals from a vast variety of other certifi cation organizations. For approval information regarding a specifi c product please contact your local SWEP representative. SWEP reserves the right to make changes without prior notice.

The BPHE concept

The Brazed Plate Heat Exchanger (BPHE) is constructed as a plate package of corrugated channel plates with a fi ller material between each plate. During the vacuumbrazing process, the fi ller material forms a brazed joint at every contact point between the plates, creating complex channels. The BPHE allows media at different temperatures to come into close proximity, separated only by channel plates that enable heat from one media to be transferred to the other with very high effi ciency. The concept is similar to other plate and frame technology, but without the gaskets and frame parts.

Form Order Product

Please complete the below order form correctly, our team will contact you shortly

Design Data Sheet
General one phase application - Heat load kW
S
L
I
D
E

1
Media S
L
I
D
E

2
Media
Temperature in
°C
Temperature in
°C
Temperature out
°C
Temperature out
°C
Flow rate
l/min
Flow rate
l/min
Max Pressure drop
kPa
Max Pressure drop
kPa
Evaporator and economizer application - Heat load kW
Slide 1
Evaporated Media
Media Slide 2
Media to be cooled
Media
Evap temp. (dew point)
°C
Temperature in
°C
Superheating
K
Temperature out
°C
Flow rate
kg/h
Flow rate
l/min
Max Pressure drop
kPa
Condenser and desuperheater applications - Heat load kW
Slide 1
Condensing Media
Media Slide 2
Media to be heated
Media
Hot Gas Temperature in
°C
Temperature in
°C
Cond. Temperature
°C
Temperature out
°C
Sub Cooling
K
Flow rate
l/min
Flow Rate
kg/h
Max Pressure drop
kPa
Addtional Information