Blast ChillerFreezer Refrigeration Controllers



HACCP: A POSITIVE SOLUTIONS
The XB570L controller is dedicated to blast chiller applications and gives a solution to HACCP system.  
                                         
With the XB570L, food is rapidly cooled (both at +3°C and at –18°C) immediately after it has been cooked, to avoid the proliferation of bacteria that occurs when food is allowed to cool naturally or in a normal refrigerator.    

Ease of use and complete management of each blast chilling phase is guaranteed by 4 cycles that can be adjusted to suit any type of food. It is possible to display the temperature of either the air or the food insertion probe.


XB Blast Chiller / Freezer Refrigeration Controllers

  • Four configurable cycles: pre-set according to the most common food – safety applications: soft chill, hard chill and freezing
  • Output for remote display to monitor the core temperature of goods
  • Internal real time clock
  • Printer output (XB07PR) for temperature and blast chiller cycles reports
  • All different phases monitorated and shown on the display
  • Ultra violet sterilization cycle management
  • Standard communication protocol ModBUS-RTU
  • Hot Key 128 or Prog tool kit connector for a quick and easy programming
  • 5VA max power absorption
  • Dual display with red LED (8.0mm high) and yellow LED (5.6mm high) and 14 icons

HACCP: A POSITIVE SOLUTIONS
The XB570L controller is dedicated to blast chiller applications and gives a solution to HACCP system.  
                                         
With the XB570L, food is rapidly cooled (both at +3°C and at –18°C) immediately after it has been cooked, to avoid the proliferation of bacteria that occurs when food is allowed to cool naturally or in a normal refrigerator.    
                                                                       
Ease of use and complete management of each blast chilling phase is guaranteed by 4 cycles that can be adjusted to suit any type of food. It is possible to display the temperature of either the air or the food insertion probe.                       
                                     
The hygiene of the blast chiller is guaranteed by an extra configurable output for sterilization by means of ultraviolet rays.

The optional XB07PR printer can be connected to the XB570L controllers to provide the user with a written report of all the main data required: cycle start and stop times, duration, the temperature of the product or the coldroom, all at regular intervals, via an internal time clock

FREEZING CYCLE: HOW IT IS ACHIEVED.
The XB570L has 4 different soft and hard chill cycles in it’s memory. These can also be modiá¼€ed by the User. Each cycle is deá¼€ned with independent time and temperature parameters to set each control phase and can be combined even with the hold phase. The four cycles are directly selectable from the keyboard. The control of each cycle is carried out using the insert probe or by time duration. 

FEATURES  XB570L
First display : no. digits  ± 3 d.p.
Second display : no. digits  ± 3 d.p.
Key board : push buttons  8
Power supply  24, 110, 230Vac
Probe inputs
Thermostat  NTC / PTC
Defrost  NTC / PTC
Insert 1  NTC / PTC
Insert 2  NTC / PTC
Insert 3  NTC / PTC
Digital inputs
Alarm  configurable
Door switch  present
Relay outputs
Compressor 20A
Defrost  8A
Fans  8A
Light 16A
AUX 8A
Alarm  16A
Other
Hot Key 128 / Programming Tool Kit output present
Remote display output X-REP optional
Printer output XB07PR output
Serial output  RS485
Buzzer  present
Real time clock  present

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Form Order Product

Please complete the below order form correctly, our team will contact you shortly